1.5 Power Ratings Specifications
Model : G361-x 3Amp
6Amp
8Amp
14Amp
20Amp
25Amp
30Amp
50Amp
60Amp
100Amp
A.C. Mains Input Range
Minimum
Maximum
65Vac (110Vac -
40%)
506Vac (440Vac +10%)
Frequency Range
50 - 60Hz
Internal Regeneration Power
Continuous Dissipation
Peak Dissipation @ 230Vac
Peak Dissipation @ 400Vac
50W
1.3Kw
4.8kW
100W
1.3kW
4.8kW
N/A N/A N/A N/A N/A N/A N/A N/A
External Regeneration Power
Continuous Dissipation
Peak Dissipation @ 230Vac
Peak Dissipation @ 400Vac
50W
1.3Kw
4.8kW
100W
1.3kW
4.8kW
200W
3.1kW
12.5kW
250W
4.85kW
19.4kW
370W
13.3kW
53.3kW
370W
13.3kW
53.3kW
370W
13.3kW
53.3kW
750W
16kW
64kW
750W
16kW
64kW
1kW
36kW
146kW
Softstart Peak Inrush
Current/Phase
30Apk
Power Supply Fault Detection
D.C. Bus Overvoltage
D.C. Bus Undervoltage
Bridge Temperature Fault
Amplifier Short Circuit Protection
24V Logic Backup Monitoring
Voltage Discharge after A.C
Mains Removal
Bleed Resistors across high voltage section.
Table 1.3 DS2100 Power Ratings