SECTION 3: WIRING AND INSTALLATION
DS2100 User's Manual
C27750-001 PAGE 3-9
3.2 Equipment Mounting
This section details the mechanical dimensions of the DS2100 chassis, as well as required clearances for cabling etc.
The DS2100 is designed to be panel or cabinet mounted. The DS2100 must be mounted in a vertical orientation. The
DS2100 must be panel mounted within an enclosure or cabinet that provides a degree of ingress protection against
liquids and objects of at least IP54. Such enclosures or cabinets must be accessible to technically qualified service or
maintenance persons only. It is recommended that the cabinet be ventilated using filtered or conditioned air, free of
corrosive or electrically conductive contaminants. The accumulation of dust, dirt, etc. on the equipment must be
avoided. A minimum clearance above and below each of the DS2100 drive sizes is required. These distances are
detailed in Table 3.3-1.
DS2100 Size Minimum Clearance Top
(mm)
Minimum Clearance Bottom
(mm)
µA & A
60 100
B 60 100
C 80 160
D 100 200
E 200 300
Table 3.3-1 Minimum Clearance around DS2100 Drives
If any of the DS2100 units are mounted in a closed cabinet, allow 100mm clearance at the front for cable bends.