DS2100 User's Manual SECTION 6:CANOPEN INTERFACE
PAGE 6-14 C27750-001
For receive PDO’s, the event time specifies the maximum time allowed between successive receptions of the PDO.
If the event time expires before the next receive event for the PDO then a ‘RPDO fault’ is detected and the drive
transitions to a level 2 fault state. If this parameter is 0 then there is no maximum time enforced.
For transmit PDO’s, the event time specifies the maximum time between successive transmissions of the PDO. This
maximum time is enforced for all types of transmit PDO. If this parameter is 0 then there is no maximum time
enforced.
6.8.5 PDO mapping
The PDO mapping is the mechanism that allows the user to change the contents of the process data objects. To
change the PDO mapping, the parameter pdo_xxxx_number_elements
should be set to 0, then the new parameters
that should be mapped written in the pdo_xxxx_mapping
array and then the number of mapped parameters should be
written into pdo_xxxx_number_elements
. Make sure that not more than 8 bytes are used up in this mapping
process. If trying to map more than 8 bytes into one PDO, writing of pdo_xxxx_number_elements
will cause an
error.