SECTION 4: GETTING STARTED
DS2100 User's Manual
C27750-001 PAGE 4-19
4.15.3 Step Response With Velocity p-gain = 0.01 & i-gain = 0.0
The following step responses were obtained using a G464-804 Global motor with resolver feedback and under no-load
conditions.
Click enable button ( )
The Oscilloscope should trigger and the status prompt should turn red and read “Stopped”
Disable drive using disable button ( ).
Figure 4.31 Step Response With Velocity p-gain = 0.01 & i-gain = 0.0