Moog MP-201 User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
MP-201 Users Manual
Page 20
MP-201 Users Manual
Page 21
Edit Mode Menus
The menu trees shown on the following pages will assist you in navigating through the
available Preset editing parameters. Note that the menus are dynamic, which means
that the available parameters change based on the selected Channel Mode.
The menu trees show the parameters, values and descriptions for each menu item.
Control Voltage values are displayed as a range from 0 4095 (‘PRECISION’ units
- the factory default view), which represents the total programmable voltage range.
If you’d rather work in volts, you can change the view from ‘PRECISION’ to ‘VOLTS’
using the DISPLAY UNITS Utilities menu (page 42).
All control voltages have a total programmable range of +/-5V (bipolar). As shipped
from the factory, however, the Multi-Pedal is congured for a unipolar range of 0-5V.
If you wish to work with bipolar voltages, go to the CV SCALE Utilities menu (page
40) and select ‘BIPOLAR’.
NOTE: The choice of CV Scale (Unipolar or Bipolar) affects all
CV parameters globally.
PRECISION values have a total range of 0 - 4095 regardless of whether the CV
voltage range is Unipolar or Bipolar. This means that a precision value of ‘0’ can
indicate either 0 Volts (in Unipolar mode), or -5V (in Bipolar mode). The tables below
show the how to interpret the values:
UNIPOLAR
Value = Volts Value = Precision
0 0
+1.25 1024
+2.50 2048
+3.75 3072
+5.00 4095
BIPOLAR
Value = Volts Value = Precision
-5.00 0
-2.50 1024
0 2048
+2.50 3072
+5.00 4095
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 51 52

Comments to this Manuals

No comments